Page 1 - Installation

Envirosorb2 7 / 12 / 14Installation and Servicing

Page 2

0020117819_01 - 05/11 - Glow-worm- 8 -3.2 Regulations 3.2.1 Statutory requirementsIMPORTANTWhere no British Standards exists, materials and equipment

Page 3 - TABLE OF CONTENTS

0020117819_01 - 05/11 - Glow-worm- 9 -5 Guarantee / Responsibility5.1 Detailed guarantee Thank you for installing a new Glow-worm appliance in your h

Page 4

0020117819_01 - 05/11 - Glow-worm- 10 -TECHNICAL DATAiThis technical data is valid for a new appliance with its own heat exchangers.6 EnvirosorbDescri

Page 5

0020117819_01 - 05/11 - Glow-worm- 11 -Description Unit 7 12 14ElectricalSupply voltage/frequency V/Hz 1/N/PE 230V 50HzFuse 15 type B 25 type D 25 typ

Page 6

0020117819_01 - 05/11 - Glow-worm- 12 -• Do not place near to stale air extraction fans.• Allow room for electricity cables (high and low voltage).•

Page 7

0020117819_01 - 05/11 - Glow-worm- 13 -7.2 Clearances - Respect the minimum dimensions shown in the drawing above in order to ensure a correct air fl o

Page 8

0020117819_01 - 05/11 - Glow-worm- 14 -8 Installing the command unit• Make sure that the materials used for performing the installation are compatib

Page 9

0020117819_01 - 05/11 - Glow-worm- 15 -2.3 Protection against the sharp edges of the sheet metal for the cable passage (if necessary)(x1)2.4 Leak-

Page 10 - INTRODUCTION

0020117819_01 - 05/11 - Glow-worm- 16 -9.3.2 Envirosorb 12, Envirosorb 1415015060090832613639.3.3 Command unit1234567132271329.4 Mounting 9.4.1 Unp

Page 11

0020117819_01 - 05/11 - Glow-worm- 17 -9.4.2 Transportation of the applianceiWith regards to the Manual Handling Operations, 1992 Regulations, the fo

Page 13

0020117819_01 - 05/11 - Glow-worm- 18 -10 Examples of installation10.1 Installation with hydraulic module, control by control unitABHEF230V230VL5162

Page 14 - INSTALLATION

0020117819_01 - 05/11 - Glow-worm- 19 -Key1 Heat pump2 Power supply and electrical protection for the heat pump (*)3 Command unit for the heat pump4

Page 15

0020117819_01 - 05/11 - Glow-worm- 20 -10.2 Installation with hydraulic module, DHW tank, control by control unitABHEF230V230VL5230V1982 36.166.27514

Page 16

0020117819_01 - 05/11 - Glow-worm- 21 -Key1 Heat pump2 Power supply and electrical protection for the heat pump (*)3 Power supply and electrical pro

Page 17

0020117819_01 - 05/11 - Glow-worm- 22 -11 Hydraulic connection• Take care to clean the pipes before assembly removing any debris or burrs. Grease and

Page 18

0020117819_01 - 05/11 - Glow-worm- 23 -- weather resistant.- equipped with wires adapted to appliance’s power rating.• Connect the heat pump to an el

Page 19

0020117819_01 - 05/11 - Glow-worm- 24 -ʎPPʎPPʎPPʎPP• Attach the electrical cables using the cable pass-through located in the elect

Page 20

0020117819_01 - 05/11 - Glow-worm- 25 -13.5.2 Board of power 7kWRRWWCCYAYYRWCVCCWRbRSC40CF1237CM1231R41CF218CM2112P25P24P23P22P21P20P35P34P19P18P04P0

Page 21

0020117819_01 - 05/11 - Glow-worm- 26 -13.5.3 Board of power 12kWRWCY/GWRW GCGOOAP R BCW C YYBBOOCWRRRWWCCBAPE9bbabb+])2LLNNC)23C)234C

Page 22

0020117819_01 - 05/11 - Glow-worm- 27 -13.5.4 Board of power 14kWRCWCABCWRGWR1TB230V1~50HzLN2TB1 2 3J4.1//2.10J3.1//2.03J1.1//2.08U V W63C

Page 23

- 1 -INTRODUCTION1 Instructions guidance ...

Page 24

0020117819_01 - 05/11 - Glow-worm- 28 -14 CommissioningiAt the time of commissioning, complete all relevant sections of the Benchmark Checklist locate

Page 25

0020117819_01 - 05/11 - Glow-worm- 29 -Envirosorb 7 fl ow/pressure curvesAB0102030405060720 1440 2160 2880123Key1 Speed I2 Speed II3 Speed IIIA Availa

Page 26

0020117819_01 - 05/11 - Glow-worm- 30 -Code Function DescriptionSettingFactory settingModifi ableparameterMin Max1Default functioning modeChoose the de

Page 27

0020117819_01 - 05/11 - Glow-worm- 31 -15.2.5 After-sales service parametersThis menu lets you make adjustments to the following functions according

Page 28

0020117819_01 - 05/11 - Glow-worm- 32 -Predefi ned heating curves (code 112)3020405060AB-20 -15 -10 -5 0 5 10 15 20121110987Key7 Heating graph n°78 H

Page 29

0020117819_01 - 05/11 - Glow-worm- 33 -Code Function DescriptionSettingFactory settingModifi ableparameterMin Max126Confi gurations exterior sensorChoos

Page 30

0020117819_01 - 05/11 - Glow-worm- 34 -Code Function DescriptionSettingFactory settingModifi ableparameterMin Max146Confi guration for stopping the heat

Page 31

0020117819_01 - 05/11 - Glow-worm- 35 -MAINTENANCEiAny work carried out on the refrigerant circuit must be conducted by qualifi ed engineers.The faults

Page 32

0020117819_01 - 05/11 - Glow-worm- 36 -18 ServicingTo ensure the continued effi cient and safe operation of the appliance it is recommended that it is

Page 33

Notes: [1] Installers should be members of an appropriate Competent Persons Scheme. [2] All installations in England and Wales must be notified to Loca

Page 34

- 2 -13 Electrical connection ... 2213.

Page 35

Service RecordIt is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed.Service P

Page 39 - [3] Built In Provided

0020117819_01 - 05/11GLOW-WORMNottingham Road, Belper, Derbyshire. DE56 1JTBecause of our constant endeavour for improvement, details may vary slight

Page 40 - Service Record

0020117819_01 - 05/11 - Glow-worm- 3 -INTRODUCTION1 Instructions guidance1.1 Product documentationThe instructions are an integral part of the applian

Page 41

0020117819_01 - 05/11 - Glow-worm- 4 -2.2 Data labelThe data label certifi es the country where the appliance is intended to be installed.Data label lo

Page 42

0020117819_01 - 05/11 - Glow-worm- 5 -2.4.2 In defrosting and cooling mode213 456Key1 Finned heat exchanger2 Reverse cycle valve3 Ventilating fan4 C

Page 43

0020117819_01 - 05/11 - Glow-worm- 6 -2.5 Hydraulic and refrigerant schematic910111214151617192022232118241324567AC138BKey1 Fan (1 fan for the 7 kW

Page 44 - GLOW-WORM

0020117819_01 - 05/11 - Glow-worm- 7 -3 Safety instructions and regulations3.1 Safety instructionseIncorrect installation can cause electric shock or